Meo Class4 Purifiers And Clarifier Important Topics

  Here I have tried my level best to list almost all possible questions from Purifiers And Clarifiers. As it is impossible to answer all questions at a time I am doing it on timely basis. If you find that I have missed out any questions, please hint me by commenting below or mail at admin@marinesite.info. Repeatedly asked questions marked as V.imp and imp so please do give special attention for those questions
  If interested in answering unanswered questions please do mail us admin@marinesite.info. Your small contribution can make a big change in someone’s life

Basics
Centrifugal Purifiers Basic Principle and Working
> How & Why back pressure maintained in Purifier? 
> What is weak link in Purifier? location? Function?
> Why lube oil in purifier is not heated above 90 degree Celsius?
> Where Pilot valve is located? Function? Working (Imp)

Procedures

Trip, Alarms, Safeties 
Safeties, Alarms And Shutdowns In Marine Purifier (Imp)

Maintenance
> Purifier Overhauling 
> Routine Checks, Maintenance Normal Parameters 

Troubleshooting 
> Marine Purifier Overflowing Reasons (Imp)

5 Comments


>> Your Comments are always appreciated...
>> Discussion is an exchange of knowledge It Make the Mariner Perfect.... Please Discuss below...

  1. Can you please explain function of pilot valve?

    ReplyDelete
    Replies
    1. plainly speaking, pilot valves help to seal the closing water because of centrifugal force. It also helps to drain the closing water when the opening water acts on it...

      Delete
  2. What is wear link in purifier, location

    ReplyDelete
    Replies
    1. Weak Links is provided to connect gear pump and horizontal shaft.... In case of any problem with gear pump, weak link breaks. Which will help to avoid the damage of horizontal shaft, gears and bearings

      Delete
  3. weak link is provided btwn motor and horizontal shaft to break link incase of motor overload to avoid damage of gear and shaft

    ReplyDelete